06-35 Push on fittings

Question: 06-35 Code Section: 7 Date: OBC 2006 Reference: 7.2.10.4. Question: The old and new Regulation does not address the “push-on” type copper fittings recently brought on to the market, except maybe 7.2.10.4. Are these fittings certified to the proper standard and are they acceptable to the regulation for use? Interpretation: Unless a product bears

06-35 Push on fittings Read More »

10-25 Trap angle

Question: 10-25 Code Section: 7 Date: 26 October 2010 OBC 2006 Reference: 7.2.3.1 (1)(a), 7.4.5.5.(2) Question Submitted: Please see the attached photo, I feel that the trap angle may compromise the trap seal. There are four traps, two service the laundry room 2″drain and two service the showers 2″ drain, any help and code references

10-25 Trap angle Read More »